15'-24' hopper assembly – Grain Systems Tanks PNEG-1070 User Manual
Page 35
5. 15'-24' Hopper Assembly
PNEG-1070 15', 18', 21', 24', 27' and 30' CHT’s
35
Begin assembling the hopper bottom by attaching a right and left pair or pairs of hopper panels to the
compression angle ring (3/8" x 1" bin bolt (S-455)) and discharge collar (1/2" x 1" hardware (S-4492)) at
four (4) opposing points as shown in
. Caulking is required on the vertical seams of the lapped
hopper panels (Refer to
). Splice plates which join the compression angle segments on the
back side may be installed following a pair of hopper panels. Refer to
. Complete this assembly
by laying in alternate right and left panels moving around in one direction and lapping all sheets the
same way,
. Do not tighten bolts until all hopper panels are attached to each other, the
compression angle, splice plates and discharge collar.
On 15' through 24' tanks use 1/2" bolts on hopper seams.
NOTE: All bolts used in hopper assembly should be installed with the bolt heads to the inside of
the hopper.
Figure 5D Hopper Panel and Discharge
Collar Assembly
Figure 5E Lap Detail (Viewed from Inside of Bin)
Figure 5F Hopper Panel Detail
Figure 5G Caulking Detail
Figure 5H
Start at the bottom of the hopper and tighten all bolts, including anchor bolts, discharge collar, hopper
panels, splice plates and compression angle segments.
Detail B
Detail A