4. Electrical Power Supply
PNEG-900 Series 2000 Autoflow Fan/Heater and Control Installation Instructions
39
Electrical Load Information
The
provide information for the electrician wiring the grain dryer and are a reference guide for
parts. It is recommended that you contact your local power company and have a representatives survey
the installation to see that the wiring is compatible with their system and that adequate power is supplied
to the unit. NOTE: The only thing connected to the recommended service amps should be the grain dryer.
Standard electrical safety procedures should be used. (Refer to the National Electrical Code Standard
Handbook by the National Fire Protection Association.) A qualified electrician should make all electrical
wiring installations.
Dryer Fan Size
Voltage
Horsepower
Full Load Amps
Fuse (Slow Blow)
Breaker
36"
220V 1 PH
15
78
150
150
208V 3 PH
15
44
125
125
220V 3 PH
15
39
100
100
380V 50 Hz
15
27
80
80
460V 3 PH
15
20
50
50
575V 3 PH
15
16
40
40
40"
220V 1 PH
15
78
150
150
208V 3 PH
15
44
125
125
220V 3 PH
15
39
100
100
380V 50 Hz
15
27
80
80
460V 3 PH
15
20
50
50
575V 3 PH
15
16
40
40
42"
208V 3 PH
30
80
150
150
220V 3 PH
30
74
150
150
380V 50 Hz
30
39
100
100
460V 3 PH
30
37
100
100
575V 3 PH
30
30
80
80
42"
208V 3 PH
40
108
200
200
220V 3 PH
40
102
200
200
380V 50 Hz
40
47
100
100
460V 3 PH
40
51
100
100
575V 3 PH
40
40
100
100