Axles cab service refill capacities, Tires, Sound – Milton CAT 962K User Manual
Page 15
Axles
Cab
Service Refill Capacities
Front
Fixed
Rear
Maximum Single-
Wheel Rise and Fall
Oscillating
± 13 degrees
481 mm
18.9 in
Tires
• Choose from a variety of tires to match
your application.
• Choices include:
23.5R25 VSW BS L2 Radial
23.5R25 VUT BS L2 Radial
750/65R25 VLT BS E3/L3 Radial
23.5R25 VJT BS E3/L3 Radial
23.5-25 SRG LD FS L3 Bias
23.5R25 XHA2 MX L3 Radial
23.5R25 XHA MX L3 Radial
23.5R25 VMT BS L3 Radial
725/70-25 LS 150 Titan L4 Bias
23.5R25 XLDD2 MX L5 Radial
Cat Flexport™
• NOTE: In certain applications (such as load
and carry), the loader's productive capabilities
might exceed the tires’ tonnes-km/h (ton-mph)
capabilities. Caterpillar recommends that
you consult a tire supplier to evaluate all
conditions before selecting a tire model.
Other special tires are available on request.
ROPS/FOPS
Meets SAE and
ISO standards
• Cat cab with a four post integrated Rollover
Protective Structure (ROPS) are standard
in North America and Europe.
• ROPS meets SAE J1040 APR88 and
ISO 3471:1994 criteria.
• Falling Objects Protective Structure (FOPS)
meets SAE J231 JAN81 and ISO:1992
Level II criteria.
Sound
• The sound values indicated below are
for specific operating conditions only.
Machine and operator sound levels will vary
at different engine and/or cooling fan speeds.
Hearing protection may be needed when
the machine is operated with a cabin that is
not properly maintained, or when the doors
and/or windows are open for extended
periods or in a noisy environment.
• The operator sound pressure level for a
standard machine configuration, measured
according to the procedures specified
in ISO 6396:2008, is 71 dB(A) with the
cooling fan speed set at maximum value.
• The machine sound power level for a
standard machine configuration, measured
according to the procedures specified
in ISO 6395:2008, is 110 dB(A) with the
cooling fan speed set at maximum value.
• The machine sound pressure level for a
standard machine configuration, measured
according to the procedures specified in
SAE J88:2006, is 75 dB(A). The measurement
was conducted under the following conditions:
distance of 15 m (49.2 ft), moving forward
in an intermediate gear ratio, static hydraulic
cycle (with no payload) and with the
cooling fan speed set at maximum value.
• The operator sound pressure level for a
machine installed with a Low Sound package,
measured according to the procedures
specified in ISO 6396:2008, is 69 dB(A) with
the cooling fan speed set at maximum value.
• The machine sound power level for a machine
installed with a Low Sound package,
measured according to the procedures
specified in ISO 6396:2008, is 107 dB(A) with
the cooling fan speed set at maximum value.
Fuel Tank –
314 L
83 gal
Standard
Cooling System
60 L
15.9 gal
Crankcase
18 L
4.8 gal
Transmission
43 L
11.4 gal
Differentials and
43 L
11.4 gal
Final Drives – Front
Differentials and
43 L
11.4 gal
Final Drives – Rear
Hydraulic Tank
189 L
49.9 gal
• All non-road Tier 4/Stage IIIB and IV,
and Japan (MLIT) Step 4 diesel engines
are required to use:
– Ultra Low Sulfur Diesel (ULSD) fuels
containing 15 ppm (mg/kg) sulfur or less.
Biodiesel blends up to B20 are acceptable
when blended with 15 ppm (mg/kg)
sulfur or less ULSD and when the
biodiesel feedstock meets ASTM D7467
specifications.
– Cat
®
DEO-ULS™ or oils that meet the
Cat ECF-3, API CJ-4, and ACEA E9
specifications are required.
15