beautypg.com

C&H Technology PM800HSA060 User Manual

Page 7

background image

PM800HSA060
Intellimod™ Module
Half Phase IGBT Inverter Output
800 Amperes/600 Volts

678

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

TIME, (s)

TRANSIENT IMPEDANCE, Z

th

(j-c)

, (NORMALIZED VALUE)

TRANSIENT THERMAL

IMPEDANCE CHARACTERISTICS

(IGBT)

10

1

10

-1

10

0

10

1

10

0

10

-1

10

-2

10

-3

SINGLE PULSE
STANDARD VALUE = R

th(j-c)Q

= 0.06

o

C/W

10

-2

10

-3

TIME, (s)

TRANSIENT IMPEDANCE, Z

th

(j-c)

, (NORMALIZED VALUE)

TRANSIENT THERMAL

IMPEDANCE CHARACTERISTICS

(FWDi)

10

1

10

-1

10

0

10

1

10

0

10

-1

10

-2

10

-3

SINGLE PULSE
STANDARD VALUE = R

th(j-c)D

= 0.09

o

C/W

10

-2

10

-3

FAULT OUTPUT PULSE WIDTH VS.

TEMPERATURE (TYPICAL)

JUNCTION TEMPERATURE, T

j

, (

o

C)

FAULT OUTPUT PULSE WIDTH % (NORMALIZED)

-20

20

60

100

140

0.7

0.8

0.9

1.0

1.1

0

1.2

V

D

= 15V

10

0

11

12

13

15

CONTROL SUPPLY VOLTAGE TRIP-RESET

LEVEL TEMPERATURE DEPENDANCY

(TYPICAL)

JUNCTION TEMPERATURE, T

j

, (

o

C)

UV TRIP-RESET LEVEL,

UV, UV

r

, (VOLTS)

100

-20

20

60

UV

t

UV

r

14

140