CPS
Vishay Dale
Wirewound Resistors,
Commercial Power, Radial Terminals
End-of-Life Vishay Dale Product
Please reference the Vishay Dale CPR as an alternative
option (for CPR datasheet please visit our website:
http://www.vishay.com/doc?30219.
FEATURES
• Direct mounting on printed circuit board
• Circuit board lock-in mounting tabs
• High performance for low cost
* Pb containing terminations are not RoHS compliant, exemptions may apply
STANDARD ELECTRICAL SPECIFICATIONS
GLOBAL
MODEL
POWER
RATING
P
70 °C
W
RESISTANCE RANGE
Ω
± 5 %, ± 10 %
TCR
± 600 ppm/°C
TCR
± 300 ppm/°C
CPS04
4
R10 - R99
1R0 - 1K0
CPS05
5
R10 - R99
1R0 - 2K0
CPS07
6.5
R10 - R99
1R0 - 2K7
Available
Pb-free
RoHS*
COMPLIANT
e3
Derating
0
20
40
60
80
100
120
- 65
AMBIENT TEMPERATURE IN °C
RATED POWER IN
%
70
50
150
250
350
TECHNICAL SPECIFICATIONS
PARAMETER
UNIT
CPS CHARACTERISTICS
Operating Temperature Range
°C
- 65 to + 350
Short Time Overload
-
5 x rated power for 5 s
Terminal Strength
lb
10 minimum
Maximum Working Voltage
V
(
P x R)
1/2
PERFORMANCE
TEST
CONDITIONS OF TEST
TEST LIMITS
Load Life
1000 h at rated power, 1.5 h “ON”, 0.5 h “OFF”
± 3.0 %
ΔR average
Climatic Sequence
1000 cycles, - 55 °C to + 125 °C
± 2.0 %
ΔR
Damp Heat, Steady State
+ 40 °C, 93 % RH, 56 days
± 2.0 %
ΔR
Resistance to Solder Heat
+ 260 °C, 10 s
± 0.2 %
ΔR typical
Low Temperature Operation
- 65 °C, full rated working voltage for 45 min
± 3.0 %
ΔR
GLOBAL PART NUMBER INFORMATION
Global Part Numbering Example: CPS05P100R0KE14
GLOBAL
MODEL
TERMINAL
VALUE
TOLERANCE
PACKAGING
SPECIAL
CPS04
CPS05
CPS07
P = /2
R = Decimal
K = Thousand
R1500 = 0.15
Ω
1K000 = 1000
Ω
J = ± 5.0 %
K = ± 10.0 %
E14 = Lead (Pb)-free bulk
E31 = Lead (Pb)-free four layer bulk
B14 = Tin/lead bulk
B31 = Tin/lead four layer bulk
(Dash Number)
(up to 3 digits)
From 1 - 999 as
applicable
0
5
P
1
0
R
0
0
P
S
K
E
1
C
4