- 3 -

7. Turn main switch on unit to the ON (RESET) position (Figs. 1-3, pgs. 4-6).
8. Green LED(s) will illuminate when unit is powered.
9. Upon completion of wiring, secure enclosure door with screws (supplied).

Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes
and in accordance with the National Electrical Code. Use 75 C or higher rated UL insulated wiring for
connecting the unit to the mains. Replace fuses only with the same type and rating (3.5 amp/250V).

Terminal Identification:

PD16W - Power Distribution Module

1P - 16P

AC output.

1N - 16N

AC output.

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.

- 3 -