Overview:

Altronix Vertiline CCTV Rack Mount Power Supplies provide 24 power outputs in a space saving 1U EIA 19” rack mount
chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power
outputs with surge suppression. Vertiline CCTV Rack Mount Power Supplies are also available in eight (8) and sixteen
(16) output models with various power ratings.

Specifications:

Twenty-four (24) Output Rack Mount Configuration Reference Chart:

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or
moisture. This installation should be made by qualified service personnel and should conform to
all local codes and in accordance with the National Electrical Code.

Installation Instructions:

1. Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 4-5, pg. 7). Affix rubber pads to

Vertiline for shelf installation (Fig. 6, pg. 7).

2. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least

3” from any video monitors). When installing the unit in a rack allow for one half of a U spacing above the unit
for ventilation.

3. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1f, pg. 4).

Insert the plug end of the line cord into a grounded AC receptacle.

4. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 3, pg. 6).
5. Select 24VAC or 28VAC power output for cameras 1-24 with the corresponding voltage adjustment switches

(Fig. 1b, pg. 4).

6. Measure output voltage before connecting cameras. This helps avoid potential damage.

All terminals with common suffix (P) “1P, 2P ...” are the same polarity.

7. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3, pg. 6).
8. Connect the power outputs of terminals marked [1P & 1N] to the power inputs of camera 1 (Fig. 2, pg. 5).

Repeat this step for each additional camera (Outputs 2-24). After wiring is completed insert terminal block into the
corresponding connector and secure by tightening the screws.

• 115VAC 60 Hz input.
• Twenty-four (24) individually selectable 24VAC

or 28VAC power outputs with OFF position.

• Twenty-four (24) power LED indicators.
• External blade fuses or PTC protected outputs.
• Surge suppression.
• Illuminated power disconnect circuit breaker with

manual reset.

• IEC 320 - 3-wire grounded line cord (detachable).
• Removable terminal blocks with locking screw flange.
• Ease of installation saves time and eliminates costly labor.
• Compact 1U rack mount chassis.
• Fits standard EIA 19” rack.
• Units can be rack, wall or shelf mounted.

Altronix
Model
Number

Vertiline24C

24VAC or

28VAC

10 amp 24 Fused

--

3 amp 3 amp

10 amp 3 amp

UL Listed for Commercial

CCTV Equipment (UL 2044).

CUL Listed - CSA Standard

C22.2 No.1-04,

Audio, Video and Similar

Equipment.

Vertiline24CD

24VAC or

28VAC

10 amp 24

--

PTC 2.5 amp

--

Vertiline246C

24VAC or

28VAC

14 amp 24 Fused

--

3 amp 3 amp

15 amp 4 amp

Vertiline246CD

24VAC or

28VAC

14 amp 24

--

PTC 2.5 amp

--

Total

Output Cur

rent (P

ow

er)

OutputV

oltage (V

A

C)

Number of Outputs

Output Protection

Class 2 Rated P

ow

er Limited

Output Protection

Cur

rent

(max. per output)

115V

A

C 60Hz

Input Cur

rent

Agenc

y Listings

Fuse RatingMain Fuse Rating