beautypg.com

Altronix T2856 Data Sheet User Manual

T2856 open frame transformer

background image

Overview

Input:

• 115VAC 50/60 Hz, 0.5 amp.

Output:

• 28VAC/56VA (2 amp) supply current.

Electrical:

• Operating temperature: --- 20º C to 49º C ambient.

Electrical (cont’d):

• 28.7 BTU/Hr.
• System AC input VA requirement: 57.5VA.

Mechanical:

• Product weight (approx.): 1.8 lbs. (0.82 kg).
• Shipping weight (approx.): 2.5 lbs. (1.14 kg).

Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com

T2856

Open Frame Transformer

Rev. DST2856_11212012

Specifications

Transformer Dimensions

(H x W x D) (approximate)

:

2.25” (57.15mm) x 2.75” (69.85mm) x 1.87” (47.5mm)

10 9 8 7 6

PRIMARY TERMINALS

SECONDARY TERMINALS

5 4 3 2 1

2.75”

(69.85mm)

2.25”

(57.15mm)

1.87”

(47.5mm)

1.06”

(26.92mm)

3.75”

(95.25mm)

3.12”

(79.25mm)

T2856

T2856 open frame transformer provides power for electronic power supplies
and equipment including security, access control and surveillance devices.