Terminal Identification:

Terminal Legend

Function/Description

AC/AC

Low voltage AC input (24VAC or 28VAC / 175VA).

+ DC ---

12VDC / 24VDC @ 6 amp continuous output.

AC FAIL
NC, C, NO

Used to notify loss of AC power, (e.g. connect to audible device or alarm panel).
Relay normally energized when AC power is present. Contact rating 1 amp @ 28VDC.

Low Battery
NC, C, NO

Used to indicate low battery condition, (e.g. connect to alarm panel). Relay normally energized
when DC power is present. Contact rating 1 amp @ 28VDC

+ BAT ---

Stand-by battery connections. Maximum charge rate 0.7 amp.

+