Overview:

These outdoor Altronix CCTV Power Supplies provide power via four (4) protected outputs for CCTV Cameras, heaters
and other video accessories. Units are UL Listed UL2044 “U.S. and Canada for CCTV Equipment.”

Four (4) Output WPTV Reference Chart:

WPTV244175UL

24VAC 7

amp

4

3

1

2.5 amp/I max

-

1.76 amp

28VAC 6.25

amp

WPTV244300UL

24VAC 12.5

amp

4

3

1

2.5 amp/I max

-

2.7 amp

28VAC

10 amp

Specifications:

Installation Instructions:

1. Mount unit in desired location. Use hardware supplied and stainless steel fasteners.
2. Turn OFF main switch on all models (Figs. 2-3, pgs. 5-6).
3. All units are factory set for 24VAC operation.

For 28VAC operation (for models with 24VAC/28VAC option only), adjust unit prior to mounting and applying
power as follows: Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the yellow wire [24V] is connected to the terminal marked [S].

4. Before drilling WP enclosure for wire entry, remove back plate (four (4) screws) with all internal parts

(Fig. 2A, pg. 5). For suggested wire entry locations refer to (Fig. 1, pg. 4). Use weather tight NEMA 4 rated
connectors, bushings, and cables.

5. Place back plate with all internal parts (four (4) screws) back into WP enclosure (Fig. 2A, pg. 5).
6. Connect AC power to the black and white flying leads of the transformer(s) (Figs. 2-3, pgs. 5-6), secure green lead

to earth ground. Use 18 AWG or larger for all power connections.
Keep power limited (PTC protected outputs only) wiring separate from non-power limited wiring.
Minimum .25” spacing must be provided. Use separate entries.

7. Measure output voltage before connecting devices. This helps avoid potential damage.

Terminals marked [1P - 4P] are of the same polarity.
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting
the output voltage.

8. Connect devices to terminals marked [1P - 1N through 3P - 3N] on board (Figs. 2-3, pgs. 5-6), carefully observing

polarity. Connect high current device to output (4P - 4N).

9. Turn main switch to the ON (RESET) position (Figs. 2-3, pgs. 5-6).
10. Green LED will illuminate when unit is powered.
11. Upon completion of wiring, secure enclosure door with the cam lock (supplied).

Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.

- 2 -

Altronix
Model Number

Output Cur

rent

(max per output)

PTC Protected/Fused

Total Output Cur

rent

(I max)

Output

V

oltage

115V

A

C

50/60Hz Input

Cur

rent

PTC Protected Outputs

(Class 2 po

w

er limited)

Fuse Protected

Outputs

Number of

Outputs

Main Fuse Ratings

on Board

• Surge suppression.
• AC power LED indicator.
• Power ON/OFF switch / circuit-breaker.
• Unit maintains camera synchronization.

• Ease of installation saves time & eliminates costly labor.
• Spare fuses included (on fuse protected models).

Enclosure Dimensions: