Altronix PD8 Installation Instructions User Manual

Pd8 - power distribution module, Overview, Specifications: input

background image

PD8 - Power Distribution Module

Overview:

The PD8 power distribution module converts a single AC or DC input into eight (8) individually fused outputs.

Specifications:
Input:

• 28VAC or 28VDC up to 14 amp.

Outputs:

• Eight (8) individually fused outputs (fuses are rated @ 3.5 amp up to 5 amp fuses may be used).
• Surge suppression.

Fuse Ratings:

• Fuses are rated @ 3.5A/250V.

Visual Indicators:

• Power output LED indicator.

Additional Features:

• Power ON / OFF switch.

Board Dimensions (approximate):

5.25"L x 3.25"W x 1"H

Installation Instructions:

1. Mount PD8 in desired location/enclosure.
2. Connect the desired power supply output to terminals marked [INPUT] (Fig. 1a).

Note: If using DC voltage, left ter

minal is NEG. (-) and right terminal is POS. (+) (Fig. 1a).

3. Measure output voltage before connecting devices. This helps avoid potential damage.

All terminals with common suffix P “1P, 2P...” are same polarity.

4. Set power switch [SW1] to the OFF position.
5. Connect each device to terminal pairs 1 to 8, marked [1P-1N thru 8P - 8N].
6. Output fuses rated at 3.5A/250V (Replacement fuses can be rated at 5.0 amp).
7. Set power switch [SW1] to the ON position.

N

COMMON POWER OUTPUTS

P

FUSED POWER OUTPUTS

1

2

3

4

5

6

7

8

D1

INPUT

R1

LED

SW1

O

N

O

F

F

N

P

S

Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.

140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
IIPD8 - Rev. 111704

J18J

MEMBER

Fig. 1

N

COMMON POWER OUTPUTS

P

FUSED POWER OUTPUTS

1

2

3

4

5

6

7

8

D1

INPUT

R1

LED

SW1

O

N

O

F

F

N

P

S

Neg. (--- ) Pos. (+ )

Fig. 1a