3 Product description

WEIGHTRAC 31 • Profibus PA

43837-EN-131119

3.2 Principle of operation

The instrument is suitable for bulk solid applications on conveyor belts

and screw conveyors. There are application possibilities in nearly all

areas of industry.

In radiation-based measurement, a Caesium-137 or Cobalt-60 iso-

tope emits focussed gamma rays that are attenuated when penetrat-

ing the conveyor belt and the medium. The PVT detector on the lower

side of the conveyor belt receives the radiation, whose strength is

proportional to the density. The measuring principle has proven to be

very reliable in conjunction with extreme process conditions because

it measures contactlessly from outside through the conveyor belt. The

measuring system ensures maximum safety, reliability and plant avail-

ability, independently of the medium and its properties.

3.3 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

based on ISO 4180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.

Transport must be carried out in due consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause

damage to the device.

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

Up to the time of installation, the packages must be left closed and

stored according to the orientation and storage markings on the

outside.
Unless otherwise indicated, the packages must be stored only under

the following conditions:

Not in the open

Dry and dust free

Not exposed to corrosive media

Protected against solar radiation

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Relative humidity 20 … 85 %

Application area

Functional principle

Packaging

Transport

Transport inspection

Storage

Storage and transport

temperature