beautypg.com

VEGA WEIGHTRAC 31 Profibus PA User Manual

Page 71

background image

71

10 Supplement

WEIGHTRAC 31 • Profibus PA

43837-EN-131119

1

Electronic

Temperature

Count

Rate

Primary

Value

Fig. 37: WEIGHTRAC 31: Block diagram with AI FB 1 … AI FB 3 OUT values
TB Transducer Block

FB 1 … FB 3

Function Block

1 Output value, adjustable (depending on instrument type and application - see following list)

Process temperature

Vapour density

Density

Volume flow

Ground

Belt speed

Loading

Module of the PA sensors

For the cyclic data traffic, WEIGHTRAC 31 provides the following modules:

AI FB1 (OUT)

– Out value of the AI FB1 after scaling

AI FB2 (OUT)

– Out value of the AI FB2 after scaling

AI FB3 (OUT)

– Out value of the AI FB3 after scaling

Free Place

– This module must be used if a value in the data telegram of the cyclical data traffic should not

be used (e.g. replacement of temperature and Additional Cyclic Value)

A maximum of three modules can be active. By means of the configuration software of the Profibus

master you can determine the configuration of the cyclical data telegram with these modules. The

procedure depends on the respective configuration software.