12 Supplement

VEGAFLEX 86 • 4 … 20 mA/HART two-wire

44231-EN-130823

L

0

-2 mm (-0.079

")

2 mm (0.079

")

-10 mm (-0.394

")

5 mm (0.197

")

-5 mm (-0.197

")

0,15 m (5.906

"

)

0,03 m (1.18

"

)

0,1 m

(3.937

")

1

Fig. 42: Deviation VEGAFLEX 86 in coax version in water
1 Dead band - no measurement possible in this area

L Probe length

L

0

-2 mm (-0.079

")

2 mm (0.079

")

-10 mm (-0.394

")

10 mm (0.394

")

0,1 m (3.937

"

)

0,05 m

(1.968

")

0,1 m

(3.937

")

0,25 m (9.842

"

)

1

1

Fig. 43: Deviation VEGAFLEX 86 in coax version in oil
1 Dead band - no measurement possible in this area

L Probe length

Repeatability

≤ ±1 mm

Specification for safety accuracy (SIL)

Siehe Safety Manual

Influence of the superimposed gas and pressure to the accuracy
The propagation speed of the radar impulses in gas or vapour above the medium is reduced by

high pressure. This effect depends on the superimposed gas or vapour and is especially large at

low temperatures.
The following table shows the resulting deviation for some typical gases and vapours. The specified

values refer to the distance. Positive values mean that the measured distance is too large, negative

values that the measured distance is too small.