VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART four-wire Approval according to LPR radio standard User Manual
Page 69
Step response time
1)
≤
3 s
Tracking speed of the measuring window
max.
1 m/min
Beam angle
2)
-
Encapsulated antenna system
22°
-
Plastic horn antenna
10°
Emitted HF power (depending on the parameter adjustment)
3)
-
Average spectral transmission power
density
-14 dBm/MHz EIRP
-
Max. spectral transmission power den-
sity
+
43 dBm/50 MHz EIRP
-
Max. power density in a distance of 1 m
<
1 µW/cm²
Ambient conditions
Ambient, storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
For the process conditions, please also note the specifications on the type label. The lower value
always applies.
Vessel pressure
-
Encapsulated antenna system
-1 … 3 bar (-100 … 300 kPa/ -14.5 … 43.5 psi)
-
Plastic horn antenna
-1 … 2 bar (-100 … 200 kPa/-14.5 … 29.0 psig)
-
Version with adapter flange from DN 150
PP
-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)
Process temperature (measured on the
process fitting)
-40 … +80 °C (-40 … +176 °F)
Vibration resistance
-
With adapter flange
2 g at 5 … 200 Hz according to EN60068-2-6
(vibration with resonance)
-
with mounting strap
1 g at 5 … 200 Hz according to EN60068-2-6
(vibration with resonance)
Shock resistance
100 g, 6 ms according to EN60068-2-27 (mechan-
ical shock)
Electromechanical data - version IP 66/IP 67
Cable entry
1)
Time span after a sudden measuring distance change by max. 0.5 m in
liquid applications, max 2 m with bulk solids applications, until the output
signal has taken for the first time 90 % of the final value (IEC 61298-2).
2)
Outside the specified beam angle, the energy of the radar signal has a level
which is reduced by 50 % (-3 dB)
3)
EIRP: Equivalent Isotropic Radiated Power
VEGAPULS
61 • Approval according to LPR radio standard
69
11 Supplement
41714
-EN
-120301