beautypg.com

VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART four-wire Approval according to LPR radio standard User Manual

Page 29

background image

5

6

7

8

4...20mA

2

1

2

+

( )

(-)

1

Fig. 21: Electronics compartment, double chamber housing

1

Internal connection to the connection compartment

2

For indicating and adjustment module or interface adapter

Information:
The connection of an external indicating and adjustment unit is not
possible with this double chamber housing.

1

3

2

power supply

4...20mA

act

ive

pass

ive

common

IS

GN

D

5

1

/L

/N

PE

2

+

( )

(-)

6

7

8

Fig. 22: Connection compartment with double chamber housing with mains
voltage

1

Voltage supply

2

4

… 20 mA signal output active

3

4

… 20 mA signal output passive

Electronics compart-
ment

Connection compart-
ment with mains voltage

VEGAPULS

61 • Approval according to LPR radio standard

29

5 Connecting to power supply

41714

-EN

-120301