beautypg.com

4 accessories and replacement parts – VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART four-wire Approval according to LPR radio standard User Manual

Page 10

background image

The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or
concealed defects must be appropriately dealt with.

Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.

Unless otherwise indicated, the packages must be stored only under
the following conditions:

l

Not in the open

l

Dry and dust free

l

Not exposed to corrosive media

l

Protected against solar radiation

l

Avoiding mechanical shock and vibration

l

Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions
"

l

Relative humidity 20 … 85 %

3

.4 Accessories and replacement parts

The indicating and adjustment module PLICSCOM is used for
measured value indication, adjustment and diagnosis. It can be
inserted into the sensor and removed at any time.

You can find further information in the operating instructions "Indicating
and adjustment module PLICSCOM
" (Document-ID 27835).

The interface adapter VEGACONNECT enables the connection of
communication-capable instruments to the USB interface of a PC. For
parameter adjustment of these instruments, an adjustment software
such as PACTware with VEGA-DTM is required.

You can find further information in the operating instructions "Interface
adapter VEGACONNECT
" (Document-ID 32628).

VEGADIS

61 is an external indicating and adjustment unit for sensors

with single chamber housing and Ex-d double chamber housing.

It is suitable for measured value indication and adjustment of plics

®

sensors and is connected to the sensor with a four-wire, screened
standard cable up to 50 m long.

You can find further information in the operating instructions
"VEGADIS 61"

(Document-ID 27720).

VEGADIS

62 is suitable for measured value indication and adjustment

of sensors with HART protocol. It is looped into the 4 … 20 mA/HART
signal cable.

Transport inspection

Storage

Storage and transport
temperature

Indicating and adjust-
ment module

Interface adapter

External indicating and
adjustment unit

External indicating and
adjustment unit with
HART protocol

10

VEGAPULS

61 • Approval according to LPR radio standard

3 Product description

41714

-EN

-120301