Din asme – VEGA VEGAPULS 68 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual
Page 75
VEGAPULS 68 - horn antenna, swivelling holder and purging air connection
mm
inch
120 mm (4.72")
47,5 mm (1.87")
20 mm (0.79")
1
2
d
3.94"
ш 1.58"
ш 1.89"
ш 2.95"
ш 3.74"
4.72"
8.50"
16.93"
x
y
100
ш 40
120
ш 48
216
ш 75
430
ш 95
1½"
2"
3"
4"
x
y
1½"
2"
3"
4"
max.15°
(0.59")
b
D
k
x
y
G1/8
max. 7 mm
(0.28")
“X”
“X” M2:1
49 mm
(1.93")
40 mm
(1.58")
D
mm
DIN
ASME
b
k
d
DN 50
165
11,5
125
4x ø 18
DN 80
200
11,5
160
8x ø 18
DN 100
220
11,5
180
8x ø 18
D
inch
b
k
d
DN 50 / 2"
DN 80 / 3"
DN 100 / 4"
D
mm
b
k
d
2"
152,4
11,5
120,7
4x ø 19,1
3"
190,5
11,5
152,4
4x ø 19,1
4"
228,6
11,5
190,5
8x ø 19,1
D
inch
b
k
d
2"
3"
4"
6.50"
4.92"
4x ø 0.71"
8x ø 0.71"
8x ø 0.71"
6.3"
7.09"
0.45"
0.45"
0.45"
7.87"
8.66"
6"
4.75"
4x ø 0.75"
4x ø 0.75"
8x ø 0.75"
6"
7.5"
0.45"
0.45"
0.45"
7.5"
9"
Fig. 49: VEGAPULS 68 - horn antenna, swivelling holder and purging air connection
1
Purging air connection G⅛ A for mounting of a suitable adapter
2
Reflux valve - unmounted (with non-Ex optionally available, with Ex in the scope of delivery), for tube diameters
6 mm
VEGAPULS
68 • Foundation Fieldbus
75
10 Supplement
29264
-EN
-090305
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)