Operating range, Adjustment – VEGA VEGAPULS 54K enamel User Manual
Page 31
VEGAPULS 54K enamel
31
24 101-EN-041227
With "
+“ and "–“ you adjust the
percentage value for the min.
value (example 0.0 %).
The entered percentage value
is written in the sensor and the
min. distance value corres-
ponding to that percentage
value flashes.
Adjustment without medium
(adjustment independent of the level)
Key entry
Display indication
Adjust-
ment
Para-
meter
Sensor
m(d)
4.700
w.o
medium
Ad-
just-
ment
in
m(d)
(min. adjustment)
OK
OK
+
OK
OK
OK
Ad-
just-
ment
in
m(d)
0.0%
at
m (d)
XX.XXX
OK
+
–
or
The distance indication flashes
and you can choose "feet“ and
"m“.
Confirm the adjustment with
"
OK“.
2. Operating range
Without special adjustment, the operating
range corresponds to the measuring range.
It is generally advantageous to set the oper-
ating range slightly larger (approx. 5 %) for
than for the measuring range.
Example:
Min./max. adjustment: 1.270 … 5.850 m;
adjust operating range to approx.
1.000 … 6.000 m.
3. Adjustment
Max.
Min.
100 % (1.270 m) correspond
to 1200 liters
Span (4.58 m)
0 % (5.850 m) corresponds
to 45 liters
Under the menu item "
Adjustment“ you inform
the sensor of the measuring range it should
operate in.
You can carry out the adjustment with or
without medium (dry adjustment). Generally,
you will carry out the adjustment without me-
dium, as you can then adjust without a filling/
emptying cycle.
Set-up