10 annex, 1 technical data, 10 .1 technical data – VEGA VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire User Manual
Page 50
10
Annex
10
.1 Technical data
General data
M
aterials, wetted parts
-
P
rocess fitting
316L
-
A
ntenna encapsulated or hygienically
encapsulated
PTFE (TFM 1600), PFA
plated, PVDF
-
P
rocess seal with hygienically encapsu-
lated antenna
FKM (V
iton), EPDM
M
aterials, non-wetted parts
-
H
ousing
P
lastic PBT (polyester), Alu die-casting powder-
coated, 316L
-
S
eal between housing and housing
cover
NBR (
stainless steel housing), silicone (Alu/plastic
housing)
-
I
nspection window in housing cover for
PLICSCOM
P
olycarbonate (UL-746-C listed)
-
G
round terminal
316T
i/316L
T
orque of the flange screws (min.)
60 N
m (44.25 lbf ft)
W
eight
-
C
lamp, bolting, depending on size and
housing material
3.5 … 6.0
kg (7.716 … 13.22 lbs)
-
F
langes, depending on flange size and
housing material
4.2 … 15.4
kg (9.259 … 33.95 lbs)
Output variable
O
utput signal
4 … 20
mA/HART
C
ycle time
min. 1 s (dependent on the parameter setting)
S
ignal resolution
1.6 µA
F
ailure signal current output (adjustable)
mA value unchanged 20.5 mA, 22 mA, < 3.6 mA
(
adjustable)
M
ax. output current
22
mA
L
oad
see load diagram under Power supply
D
amping (63 % of the input variable)
0 … 999
s, adjustable
F
ulfilled NAMUR recommendations
NE
43
HART
output values
-
1. HART
value (Primary Value)
D
istance to the level
-
2. HART
value (Secondary Value)
D
istance to the level - scaled (for example hl, %)
R
esolution, digital
>
1
mm (0.039 in)
50
VEGAPULS
63 • 4 … 20
mA/HART - two-wire
10 A
nnex
28436
-EN
-120530