beautypg.com

Electrical connection – VEGA VEGAPULS 43 4 … 20 mA; HART compact sensor User Manual

Page 37

background image

VEGAPULS 43 – 4 … 20 mA

37

26626-EN-041227

Electrical connection

2

2

4

2

-

+

4 ... 20 mA

VEGADIS
371 Ex

Measuring system with VEGAPULS 43 on VEGADIS 371 Ex indicating
instrument with current and relay output (Ex ia)

• Two-wire technology (loop powered), intrinsically safe ia supply via the signal cable of the

VEGADIS 371 Ex indicating instrument for operation of the sensor in Ex zone 1 or Ex
zone 0.

• Optional external indicating instrument with analogue and digital display (can be mounted

up to 25 m away from the sensor).

• Adjustment with PC, HART

®

handheld or adjustment module MINICOM (can be plugged into

the sensor or into the external indicating instrument VEGADIS 50).

(passive)

VEGADIS 50

0/4 … 20 mA
(active)

Relay

(see „7.2 Approvals“)

Ex area

Non Ex area

HART

®

handheld

VEGA-
CONNECT

1)

If the resistance of the processing systems
connected to the 4 … 20 mA signal output is less
than 250

Ω, a resistor must be connected to the

connection cable during adjustment to get a loop
resistance of 250

Ω.

The digital adjustment signal would otherwise be
severely damped or short-circuited due to
insufficient resistance of the connected
processing system. Digital communication with the
PC would not be ensured.

1 )

Zone 0 or
Zone 1

EEx ia