6.4 Setup procedure

VEGABAR

61 can be used for level as well as for process pressure

measurement. Default setting is level measurement. The mode can be
changed in the adjustment menu.

Depending on the application only the respective subchapter "Level or
process pressure measurement" is of importance. There, you find the
individual adjustment steps.

Level measurement

Set up VEGABAR 61 in the following sequence:

1

Selecting adjustment unit/density unit

2

Carry out position correction

3

Carrying out min. adjustment

4

Carrying out max. adjustment

In the menu item "Adjustment unit" you select the physical unit in which
the adjustment should be carried out, e.g. mbar, bar, psi…

The position correction compensates the influence of the mounting
position or static pressure on the measurement. It does not influence
the adjustment values.

Information:
The steps 1, 3 and 4 are not necessary for instruments which are
already preset according to customer specifications!

You can find the data on the type label on the instrument or in the
menu items of the min./max. adjustment.

The indicating and adjustment module enables the adjustmetn without
filling or pressure. Thanks to this, you can carry out your settings
already in the factory without the instrument having to be installed.

The actual measured value is also displayed in the menu items for
min./max. adjustment.

In this menu item you select the adjustment unit as well as the unit for
the temperature indication in the display.

To select the adjustment unit (in the example switching over from bar
to mbar) you have to proceed as follows:

4)

1

Push the [OK] button in the measured value display, the menu
overview is displayed.

4)

Selection options: mbar, bar, psi, Pa, kPa, MPa, inHg, mmHg, inH

2

O,

mmH

2

O.

Level or process pres-
sure measurement

Parameter ad-
justment "Level
measurement"

Select unit