beautypg.com

VEGA VEGAFLEX 52P (Profibus PA) User Manual

Page 15

background image

VEGAFLEX 51P and 52P

15

Technical data

Characteristics

Min. span between full and empty adjustment

- digital output signal

10 mm

Adjustment time

2)

> 1 s (depending on the parameter setting)

Measuring range begin

300 mm below the seal surface

Measuring range end

upper edge of the gravity weight or

the cable loop

Ambient conditions

Vessel pressure

-1 … 16 bar

Ambient temperature on the housing

-40°C … +60°C

Process temperature

-40°C … +120°C

Storage and transport temperature

-60°C … +80°C

Protection

IP 66/IP 67 (meets both protections)

Protection class

- two-wire sensor

II

Overvoltage category

III

Max. tensile load

- cable ø 4 mm

5 KN

- cable ø 8 mm

20 KN

Ex technical data

StEx

Zone 10

E x

Zone 0

The permissible operating data of VEGAFLEX sensors for StEx areas are stated in the
certificate.

Process connections

VEGAFLEX 51 and 52

G 1

1

/

2

A, 1

1

/

2

" NPT

chromized steel or 1.4301 (stainless steel)

Connection cables

Two-wire sensors

power supply and signal via one
two-wire cable

Wire cross-section

generally 2.5 mm

2

Ground connection

max. 4 mm

2

Cable entry

2 x M20 x 1.5 (cable entry 5 … 9 mm)

Materials

Housing

PBT (Valox) or Aluminium (powder-coated)

Cable

1.4401 (stainless steel, 316) or

galvanized steel/PA coated