Cenelec (eex ia iic) – VEGA Capacitive electrodes EL … User Manual
Page 16
16
Capacitive electrodes EL …
Level detection with fault monitoring
Instrument
Conformity
Oscillator
Conformity
Level switch
Conformity
certificate
certificate
VEGATOR
certificate
PTB-no.
PTB-no.
PTB-no.
Capacitive electrodes
1)
Ex-96.D.2021
E15 Ex
Ex-95.D.2040 U
521 Ex, 522 Ex
Ex-95.D.2065 X
523 Ex, 527 Ex
Ex-95.D.2073 X
621 Ex, 622 Ex
Ex-96.D.2068
Capacitive electrodes
2)
Ex-96.D.2021
E18 Ex
Ex-95.D.4042 U
521 Ex, 522 Ex
Ex-95.D.2065 X
523 Ex, 527 Ex
Ex-95.D.2073 X
621 Ex, 622 Ex
Ex-96.D.2068
All instruments with appropriate oscillator type 15 Ex, E18 Ex in conjunction with safety barrier type 145 can be
connected to not-Ex-two-wire level switch VEGATOR as well as to VEGALOG 571, hence the conformity certificate
PTB-no. Ex-85.B.2038 must be noted.
1)
Type EL 11 Ex0, EL 21 Ex0, EL 24 Ex0, EL 31 Ex0, EL 42 Ex0
2)
Type EL 26 Ex0
CENELEC (EEx ia IIC)
Continuous level measurement
Instrument
Conformity
Oscillator
Conformity
Signal cond.
Conformity
Aux. level
certificate
certificate
instrument
certificate
switch
PTB-no.
PTB-no.
VEGAMET
PTB-no.
VEGASEL
or
PTB-no.
VEGATRENN
Ex-80/2160
Capacitive
Ex-95.D.2097
E17 Ex
Ex-95.D.2041 U
513 Ex, 514 Ex
Ex-95.D.2145 X
543 … 547
electrodes
1)
515 Ex
Ex-95.D.2161 X
643
602 Ex
Ex-95.D.2095
544 Ex
Ex-95.D.2145 X
Capacitive
Ex-95.D.2097
E18 Ex
Ex-95.D.2042 U
513 Ex, 514 Ex
Ex-95.D.2145 X
543 … 547
electrodes
1)
515 Ex
Ex-95.D.2161 X
643
602 Ex
Ex-95.D.2095
544 Ex
Ex-95.D.2145 X
All above mentioned instruments can be connected except the compact instruments in conjunction with safety
barrier type 145 to suitable not-Ex two-wire instruments VEGAMET as well as VEGALOG 571, hence conformity
certificate PTB-no. Ex-85.B.2038 must be noted.
1)
Type EL 11 Ex, EL 18 Ex, EL 21 Ex, EL 24 Ex, EL 28 Ex, EL 29 Ex, EL 31 Ex, EL 33 Ex, EL 34 Ex, EL 42 Ex,
EL 52 Ex, EL 53 Ex, EL 60 Ex, EL 61 Ex
Product description