beautypg.com

4 approvals, Ce-approval, Ptb-zone 0 (eex ia iic) – VEGA Capacitive electrodes EL … User Manual

Page 15

background image

Capacitive electrodes EL …

15

Product description

1.4 Approvals

The capacitive electrodes type EL are
available with the following approvals:

- explosion protection (CENELEC, Zone 0)
- overfill protection acc. to WHG, (VbF)
- dust-explosion protection Zone 10
- ship approvals (GL, LRS, ABS)

For these applications note the appropriate
legal documents (test reports, test certificates,
type approvals and conformity certificates).
These documents are supplied with the
appropriate instrument.

CE-approval

The capacitive electrodes type EL meet the
protective regulations of EMVG (89/336/EWG)
and NSR (72/23/EWG). The conformity has
been judged acc. to the following standards:
EMVG

Emission

EN 50 081 - 1

Susceptibility

EN 50 082 - 2

NSR

EN 61 010 - 1

PTB-Zone 0 (EEx ia IIC)

Continuous level measurement

Instrument

Conformity

Oscillator

Conformity

Signal conditio- Conformity

Aux. level

certificate

certificate

ning instrument certificate

switch

PTB-no.

PTB-no.

VEGAMET

PTB-no.

VEGASEL
PTB-no.
Ex-80/2160

Capacitive

Ex-96.D.2021

E17 Ex

Ex-95.D.2041 U

513 Ex, 514 Ex

Ex-95.D.2145 X

543 … 547

electrodes

1)

515 Ex

Ex-95.D.2161 X

643

602 Ex

Ex-95.D.2095

VEGATRENN
544 Ex

Ex-95.D.2145 X

Capacitive

Ex-96.D.2021

E18 Ex

Ex-95.D.2042 U

513 Ex, 514 Ex

Ex-95.D.2145 X

543 … 547

electrodes

1)

515 Ex

Ex-95.D.2161 X

643

602 Ex

Ex-95.D.2095

VEGATRENN
544 Ex

Ex-95.D.2145 X

All instruments with appropriate oscillator type E17 Ex, E18 Ex in conjunction with safety barrier type 145 can be
connected to not-Ex-two-wire level switches VEGATOR as well as to VEGALOG 571, hence the conformity
certificate PTB-no. Ex-85.B.2038 must be noted.

1) Type EL 11 Ex0, EL 21 Ex0, EL 24 Ex0, EL 31 Ex0, EL 42 Ex0