2 dimensions, Standard housing, Vegabar 17 – VEGA VEGABAR 17 User Manual
Page 30
9
.2 Dimensions
VEGABAR 17
- standard housing
G1/4
~116 mm (4.57 ")
2 mm
(0.08")
13 mm
(0.51")
2 mm
ø 5 mm
(0.20")
ø 9,5 mm
(0.37")
SW27
G1/2
~123 mm (4.84 ")
ø 27 mm
(1.06")
3 mm
(0.12")
3 mm
20 mm
(0.79")
ø 6 mm
(0.24")
ø 17,5 mm
(0.69")
G1/2
14 mm
(0.55")
10 mm
(0.39")
~119,5 mm (4.70")
G1/2
G¼
~123 mm (4.84 ")
20 mm
(0.79")
3 mm
(0.12")
ø 17,5 mm
(0.69")
G1/2
10 mm
(0.39")
ø 18 mm
(0.71")
20,5 mm
(0.81")
~126 mm (4.96")
G1
20,5 mm
(0.81")
10 mm
(0.39")
~126 mm (4.96")
ø 30 mm
(1.18")
SW41
G1
28 mm
(1.10")
~135 mm (5.31")
ø 30 mm
(1.18")
1/4NPT
1/2NPT
~116 mm (4.57")
13 mm
(0.51")
~123 mm (4.84")
19 mm
(0.75")
GBX
NBX
NDX
84L/84B
GDX
TBX
851/85L/85B
861/86L/86B
GTX
Fig. 15: VEGABAR 17 standard housing, GBX = G¼ B manometer connection, GDX = G½ B manometer
connection, GTX = G½ A according to DIN 3852-E, TBX = G½ B, inside G¼ B, 84L/84B = G1 B front-
flush max.
25
bar, 851/85L/85B = G1 B front-flush with O-ring up to 1.6 bar, 861/86L/86B = G½ B front-flush with O-ring
> 1
.6 bar, NBX = ¼ NPT thread, NDX = ½ NPT thread
30
VEGABAR
17
9 S
upplement
27636
-EN
-120531
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)