beautypg.com

VEGA VEGABAR 17 User Manual

Page 25

background image

-

V

ersion for medium temperature < -30 °C

(-22 °F)

10

ms

-

V

ersion for measuring ranges > 25 bar

10

ms

-

V

ersion with front-flush diaphragm

10

ms

Reference conditions and actuating variables (according to DIN EN 60770-1)

R

eference conditions according to DIN EN 61298-1

-

T

emperature

+

15 … +25 °C (+59 … +77 °F)

-

R

elative humidity

45 … 75 %

-

A

ir pressure

860 … 1060

mbar/86 … 106 kPa (12.5 … 15.4 psi)

D

etermination of characteristics

L

imit point adjustment according to IEC 61298-2

R

eference installation position

upright, diaphragm points downward

I

nfluence of the installation position

depending on the chemical seal version

Input variable

T

he availability of the respective measuring range depends on the corresponding process fitting.

T

he specifications on overload capacity are only an overview and refer to the measuring cell.

L

imitations due to the material and form of the process fitting are possible. The specifications on

the type label always apply.

Nominal range

Overload capacity, max.
pressure

Overload capacity, min.
pressure

G

auge pressure

-0.1 … 0

bar/-10 … 0 kPa

1

bar/100 kPa

-1

bar/-100 kPa

-0.16 … 0

bar/-16 … 0 kPa

1.5

bar/150 kPa

-1

bar/-100 kPa

-0.25 … 0

bar/-25 … 0 kPa

2

bar/200 kPa

-1

bar/-100 kPa

-0.4 … 0

bar/-40 … 0 kPa

2

bar/200 kPa

-1

bar/-100 kPa

-0.6 … 0

bar/-60 … 0 kPa

4

bar/400 kPa

-1

bar/-100 kPa

-1 … 0

bar/-100 … 0 kPa

5

bar/500 kPa

-1

bar/-100 kPa

-1 … 3

bar/-100 … 300 kPa

10

bar/1000 kPa

-1

bar/-100 kPa

0 … 0.1

bar/0 … 10 kPa

1

bar/100 kPa

-1

bar/-100 kPa

0 … 0.16

bar/0 … 16 kPa

1.5

bar/150 kPa

-1

bar/-100 kPa

0 … 0.25

bar/0 … 25 kPa

2

bar/200 kPa

-1

bar/-100 kPa

0 … 0.4

bar/0 … 40 kPa

2

bar/200 kPa

-1

bar/-100 kPa

0 … 0.6

bar/0 … 60 kPa

4

bar/400 kPa

-1

bar/-100 kPa

0 … 1

bar/0 … 100 kPa

5

bar/500 kPa

-1

bar/-100 kPa

0 … 1.6

bar/0 … 160 kPa

10

bar/1000 kPa

-1

bar/-100 kPa

0 … 2.5

bar/0 … 250 kPa

10

bar/1000 kPa

-1

bar/-100 kPa

0 … 4

bar/0 … 40 kPa

17

bar/1700 kPa

-1

bar/-100 kPa

0 … 6

bar/0 … 600 kPa

35

bar/3500 kPa

-1

bar/-100 kPa

0 … 10

bar/0 … 1000 kPa

35

bar/3500 kPa

-1

bar/-100 kPa

0 … 16

bar/0 … 1600 kPa

80

bar/8000 kPa

-1

bar/-100 kPa

VEGABAR

17

25

9 S

upplement

27636

-

EN

-120531