All wires of the output section must be at least 2.5mm².
Power supply wiring can be done with 0.5mm² wire.



Use fuse ratings as indicated on the connection examples.


Put an extra layer of solder on all tinned PCB tracks, to improve their current handling capabilities.



This unit is suitable for use with resistive loads, such as regular incandescent light bulbs.



The unit is not suitable for use with transformer operated lighting or fluorescent lighting.

17. ASSEMBLY, HOOK-UP AND USE

Assembly, Hook-up & Use



Attention : There is no transformer isolating this circuit from the mains.
Therefore, all parts of the PCB carry a potentially lethal voltage. The circuit
must be mounted in an adapted enclosure according to the applicable norms,
so that no live parts can be touched or present any other danger.