Connection


For connection between the modules, use twisted pair cable (ex. EIB 2x2x0.8mm

2

, UTP 8x0.51mm

- CAT5

or other). Use minimum 0.5mm² cable. For long wiring (>50m) or if a lot of modules ( > 10) are connected
to one wire, use 1mm² cable. Connect the 12-18Vdc (mind the polarity) and connect the bus wires (mind the
polarity).

H

L

-

+

BUS

12V

VMB4PD

L

H

-12V+

BUS

TWISTED

PAIR

(0.5mm )

2

Connect a 9V battery (via the included cable) if you desire to power the clock in case of a power failure.

12V power supply

-

+

L

H

Velbus

9V backup

+

-

battery

J

Open

Hint: for advanced level only!
Solder island “J” when using a back-up battery in order to feed the battery.

12V power supply

-

+

L

H

Velbus

+

-

J

Closed

9V backup

battery

Rechargeable

WARNING: NEVER use a regular battery (non rechargeable) when soldering island “J” to avoid
risks of explosion.