Velleman LAB1 User Manual
Page 8

8
1. DC VOLTAGE
Range
Resolution
Accuracy
200mV
100µV
±0.5% of rdg ± 2 digits
2V
1mV
±0.5% of rdg ± 2 digits
20V
10mV
±0.5% of rdg ± 2 digits
200V
100mV
±0.5% of rdg ± 2 digits
600V
1V
±0.8% of rdg ± 2 digits
Overload protection : 250Vrms for the 200mV range and 600Vdc or rms ac for other ranges
.
2. DC CURRENT
Range
Resolution
Accuracy
200µA
0.1µA
±1% of rdg ± 2 digits
2mA
1µA
±1% of rdg ± 2 digits
20mA
10µA
±1% of rdg ± 2 digits
200mA
100µA
±1.5% of rdg ± 2 digits
10A
10mA
±3% of rdg ± 2 digits
Overload protection : F 200mA / 250V fuse. (no fuse for the 10A range).
3. AC
VOLTAGE
Range
Resolution
Accuracy
200V
100mV
±1.2% of rdg ± 2 digits
600V
1V
±1.2% of rdg ± 2 digits
Overload protection : 600Vdc or rms ac for all ranges.
Frequency range : 40Hz to 400Hz. Response : average, calibration in rms of a sine wave
4. DIODE & CONTINUITY
Range
Description
If continuity exists (about less that 60
Ω), built-in buzzer
will sound
Displays the diode's approx. forward voltage drop
Overload protection : 250Vdc or rms ac
Digital multimeter