beautypg.com

Ohaus RA PRICE COMPUTING COMPACT SCALES Manual User Manual

Page 14

background image

EN-12

RA Series

6. When “

YES

” is displayed, press [+] to enter the Span Calibration

sequence.

Note: Do not change the settings of any parameters unless specified

above. Other parameters are service settings intended for authorized
servicing use only. The scale may be turned off at any time to abort setup
without saving any changes.

7. Span Calibration Sequence:

Window Display

Weight

Unit Price

Total Price

Description

Actions

CAL StEP

1 15.00

Scale capacity

Press [+] to select and proceed to next step.
Make sure the displayed value matches the
scale model capacity.
Do not press [>T<], which will toggle
through other capacity settings that may not
match the scale model’s.

Step

2 ------

Establish zero

Press [+] to initiate countdown sequence.
Ensure the pan is empty and the scale
stable.

5 ... 0

Countdown

The countdown will repeat if the scale is not
stable during this process.

Step

3 kkkkkk

2/3 calibration
point

Place 2/3 capacity weight on the pan, then
press [+]
to proceed to the next step.

Step

4 0

Full span

Enter the scale capacity value from Step 1
(e.g., “

15

”) via the numeric keypad.

15

Establish full
span

Place the indicated weight on the pan,
then press [+]
to initiate countdown
sequence.

5 ... 0

Countdown

The countdown will repeat if the scale is not
stable during this process.

Save

Save or Abort

Remove the weight from the pan, then
press [+]
to save settings and restart scale
to weighing mode.
If needing to abort calibration and retain
previous calibration data, press [>T<]
(“Abort” will be displayed) then [+] at this
time (or turn the scale off at any time during
the process).