beautypg.com

Longacre 78310 AccuLevel (version 1) User Manual

Acculevel, Ver. 1.2), Digital level measurment from 0.0

background image

AccuLevel

(Ver. 1.2)

Monroe, Wa. 360 453 2030 www.longacreracing.com

8/06

Turn on: Push “SWITCH” (hold 1 sec.)

AccuLevel™

shuts off after 5 minutes to

extend battery life.

To hold reading: Push “KEEP” (hold 1 sec.) The reading will be held on the display,

indicated by H. Push “KEEP” again (hold 1 sec.) to go back to active reading.

To calibrate: Place

AccuLevel™

on a reasonably level table top. Let it stabilize for

10 seconds. Push “TEST”. CAL1 will appear on the display. Turn around 180

O

in the

same spot, let it stabilize again for 10 seconds, and push “TEST” again. Display will
show CAL2, then go back to normal degree display. You are done.

MODE:

AccuLevel™

has 3 different modes. 1) is the primary mode and shows

absolute degrees to .1 (1/10) degree Modes 2 & 3 are used in construction trades.

Mode 2 is the % of 45

O

and Mode 3 is inches per foot of slope.

SOUND: Push this button and

AccuLevel™

will beep when it gets to 0

O

or 90

O

.

Shut the unit off when done to save battery life.

This version does not have an automatic shutoff.

Do not drop the unit. Keep it clean and dry and avoid strong

electrical or magnetic fields. Do not push 2 buttons at once.

Battery:

Remove black end cap
to access. Replace when
needed with a good
quality alkaline 9 volt.

Digital Level Measurment from 0.0

O

to 90.0

O

1.2

SWITCH

SOUND

TEST

MODE

KEEP

Pointers on display -

-

show direction of tilt.

(If AccuLevel™ is used for measuring
front end camber this will tell whether
camber is posative or negative.)

LEVEL

0.3

0.3

Note direction of pointers