beautypg.com

Longacre 78310 AccuLevel Pro (version 4) User Manual

Ver. 4)

background image

(ver. 4)

Monroe, Wa. 360 453 2030 www.longacreracing.com

9/09 Ver 4

Digital Level Measurement
from 0.0

O

to 90.0

O

Pointers on display - -
show direction of tilt.

(If

AccuLevel

is used for measuring

very small angles - under 2

O

- this feature

will tell you which way the tilt is)

LEVEL

Note direction of pointers

4.3

4.3

4.3

4.3

4.3

4.3

4.3

4.3

4.3

4.3

ON/OFF

HOLD

1.8

1.8

1.8

1.8

1.8

H

H

H

H

H

NOTE: This Ver. 4

AccuLevel™

has 2 modes of operation. 1) In Normal angle measurement

mode the display is steady. 2) In Caster Mode the display flashes (and will not measure absolute
angles). Push

CASTER

button to exit Caster mode and go back to Normal angle measurement.

Turn on: Push

ON/OFF

.

AccuLevel™

shuts off automatically after 15 minutes to save battery life.

Batteries should last a year or more in normal use. See back side for battery door. Replace with 2)
AAA alkaline batteries. Recalibrate when you change batteries (see below).

Zero:

AccuLevel™

maintains its zero when shut off and DOES NOT REQUIRE ZEROING.

Compare one angle to another: The

ZERO

button is ONLY used to compare one angle to another. Place

AccuLevel™

on a surface and push

ZERO

. The display will go to 00.0

00.0

00.0

00.0

00.0

and will disappear

from display. Move to a different surface to compare the difference. Push

ZERO

again to return to

normal use.

To hold a reading: Push

HOLD

and release. The display will show

H

H

H

H

H

and flash. When

H

H

H

H

H

stops

flashing (approx. 5 sec.) the reading is held on the display. Push

HOLD

again to go back to active

reading. NOTE:

AccuLevel™

MUST be held absolutely steady during this 5 seconds.

To CALIBRATE: Place

AccuLevel™

on a reasonably level surface (does not need to be per-

fectly level). Turn on, then push

ON/OFF

again and hold for 5 seconds until unit shuts off. Turn unit on

again and

-

-

-

-

-

1

1

1

1

1

-

-

-

-

-

will appear on the display. Now push

ZERO

.

-

-

-

-

-

1

1

1

1

1

-

-

-

-

-

H

H

H

H

H

will begin to flash and in a few

seconds

-

-

-

-

-

2

2

2

2

2

-

-

-

-

-

will appear.

Turn unit around 180

O

in the same spot and push

ZERO

again.

-

-

-

-

-

2

2

2

2

2

-

-

-

-

-

H

H

H

H

H

will begin to flash and in a few seconds normal readings will reappear. Calibration is now complete.

CASTER

(CASTER)

:

AccuLevel™

will display front suspension Caster when used in a specially

designed Caster/Camber gauge (see Longacre catalog or website). See gauge instructions for details.

DISPLAY BACKLIGHT

(LIGHT)

:

AccuLevel™

Ver. 4 has a display back light.

Do not drop the unit. Keep it clean and dry and avoid strong electrical or magnetic fields. Do

not push 2 buttons at once. If it will not be used for several months remove batteries.

LIGHT

ZERO

DIGITAL LEVEL

CASTER

Must be on
display for
normal use.
Push

ZERO

if it is not.

H

H

H

H

H

will ONLY be

on if the unit is
Holding a reading
or in calibration