Airway Resistance Compensation (ARC)

Note: Not available in Neonatal option

Type of
compensation:

Electronic tube compensation

Compensation for: Endotracheal and tracheostomy tubes

Tube diameter:

5 to 10 mm

Level of
compensation:

25 to 100%

Mode Families

Allows user adjustment to specify certain parameters that
align with the hospital’s current ventilator usage.

Adjustable
parameters:

Flow and Inspiratory timing

Family 1:

Flow control is On/Insp. Timing is I:E

Family 2:

Flow control is Off/Insp. Timing is I:E

Family 3:

Flow control is On/Insp. Timing is T

insp

Family 4:

Flow control is Off/Insp. Timing is T

insp

Family 5:

Flow control is On/Insp. Timing is T

pause

Ventilator Monitoring

Airway pressure

–20 to +120 cm H

2

O

Patient flow

0.1 to 32 L/min

1 to 200 L/min

Tidal volume

0.5 to 1,000 mL with Neonatal

Flow

Sensor

1 to 1,000 mL without the Neonatal

Flow

Sensor

5 to 2,500 mL

Minute volume

0 to 99.9 L/min

CO

2

0 to 30%/0 to 225 mmHg

Compliance

0.1 to 150 mL/cm H

2

O

Resistance

1 to 500 cm H2O/L/s

RQ

0.6 to 1.3

VO

2

50 to 1000 mL/min

VCO

2

50 to 1000 mL/min

Rate

0 to 150 breaths per minute

(increments of 1 breath per minute)

0 to 120 breaths per minute

(increments of 1 breath per minute)

FiO

2

10 to 100%

Rapid Shallow
Breathing Index
(RSBI)

1 to 999 bpm/L

Note: Not available in Neonatal option

Non-Invasive Ventilation (NIV) (optional)

Mask ventilation: Yes

Integrated unique leak recognition algorithm

Automatic Patient Detection (APD)

Patient
re-connection: Automatic detection in standby

Detection by:

Back pressure to Bias-fl ow

100% O

2

( O

2

)

Delivers 5 to 75% above current FiO

2

setting

for ≤ 2 minutes

Delivers 100% O

2

for ≤ 2 minutes

Can be adjusted to other O

2

%

Take Snapshot

Immediate capture and storage of critical data currently on
the Engström’s display

Stored data:

3 waveform segments

Alarm messages (up to 5, currently active)

All measured parameters

All set ventilator parameters

Maximum stored
Snapshots:

10 most recent

Cursor:

Ability to cursor across waveforms

for

specifi c measured values

Ventilator Preferences

Back-up Mode: Establishes the specifi c ventilator mode

and parameters used in the event that the
ventilator switches to Back-up ventilation

ARC:

Allows control and setting of the airway
resistance compensation

Assist Control: Allows the user to turn the Assist Control

capability On or Off

Leak
Compensation: Allows the user to turn the Leak

Compensation capability On or Off

Trigger
Compensation: Allows the user to turn On or Off

compensation for fl ow triggering

TV Based
Conditions:

Allows setting between ATPD (Ambient
Temperature Pressure Dry) or BTPS
(Body Temperature Pressure Saturated)