Appendix – American Magnetics 4Q06125PS-430 Integrated Power Supply System User Manual
Page 180
![background image](/manuals/252960/180/background.png)
162
Rev. 5
Appendix
Power Supply Details
Closed Loop Gain
Voltage Channel
0.6
Current Channel
12.5
INPUT CHARACTERISTICS
Voltage
Nominal
230 Vac
Single phase
Range
176 - 264 Vac
Frequency
Nominal
50 - 60 Hz
>65 Hz, leakage exceeds spec
Range
47 - 65 Hz
Current
176 Vac
9.5 A
Maximum
264 Vac
6.4 A
Power factor
0.99 minimum
Nominal output power, source
Efficiency
50%
Minimum, source
Switching frequency
50 KHz
PFC Stage
EMC (Electromagnetic Compatibility) Compli-
ance
EN61326-1 (1997)
Class A equipment
EMC immunity to:
ESD
EN61000-4-2
Electrostatic discharge
Radiated RF
EN61000-4-3
Radio Frequencies
EFT
EN61000-4-4
Electrical fast transient/burst
Surges
EN61000-4-5
Conducted RF
EN61000-4-6
EMC emissions
Conducted
EN61000-3-2
Harmonics
EN61000-3-3
Fluctuation & flicker
EN55011/CISPR11
0.15 to 30 MHz
Radiated
30 to 1000 MHz
Leakage current
3.5 mA
230 Vac, 47-63 Hz
Insulation coordination
Input
Installation Category II
Overvoltage Category II
Output
Installation Category II
Overvoltage Category II
Pollution degree
2
OUTPUT CHARACTERISTICS
Type of stabilizer
Voltage-current, 4-quadrant
Switch mode
Switching frequency
100 KHz
Output Stage
Source adjustment
range
Voltage
-6 V to +6 V
0 to 50°C
Current
-125 A to +125 A
Sink adjustment range
Voltage
-6 V to +6 V
0 to 50°C, recuperated energy is returned to
line
Current
-125 A to +125 A
Table A-11.
Model 4Q06125PS Electrical Specifications (Continued)
Specification
Rating / Description
Condition