beautypg.com

ACU-RITE 100S User Manual

Page 22

background image

100S

Reference Manual

19

OPERATION

Example: Incremental & Absolute Position Presets

Hole 1 is an absolute dimension because it’s measured from datum. Hole
2 is an incremental dimension (measured from one hole to the next). Hole
3 is an absolute dimension from datum.

1. Press the

ABS/INCR

key until ABS is selected on the DRO dis-

play. Also check that the system is in the “inches” mode (the MM
LED should not be lit up).

2. For Hole 1, move the table until X = 2.00” and Y = 1.5”.

Drill Hole 1.

3. Now press the

ABS/INCR

key so that INCR is selected on the

DRO display.

4. Press the

X

key and ensure the INCR led is lit. Enter

2

as the

incremental distance from Hole 1 to Hole 2, and then press

ENTER

.

Two inches is the incremental preset distance.

5. Move the table until X = 0.000” and Y = 0.000”. Drill Hole 2.

6. Press the

X

key and ensure the ABS led is lit by pressing the

ABS/INCR

key. Then enter the ABS dimension 6.0 for Hole 3, then

press

ENTER

.

7. Move the table until X = 0.000” and Y = 0.000”. Drill Hole 3.

Datum

4. Repeat the step above for another axis or press

ENTER

to return

to the DRO display.

To reach the preset position, move the table until the display for each
preset axis reads “0.”