SETUP

Move to the “Count Direction” display in the Setup mode. (Press

SETUP

and then the

ENTER

key until “Ct dir” appears).

Press the appropriate axis key (

X

,

Y

or

Z

) until the

count direction

(1 or 2) appears.

After you complete setting your count direction, press

ENTER

to con-

tinue with setup or press

ENTER

then

SETUP

to return to the normal

DRO display.

To change the count direction:

Count Direction

Use the count direction setting to define the positive counting direction
for each scale. The direction will be displayed as a “1” or a “2” (the
numbers are not assigned to a particular direction). You only need to
change the count direction if the scale is counting in the negative
direction during a positive table move, or vice versa.

Refer to Conventions on pg. 37 for more guidelines.

Position Recall

Set this parameter to the ON position to store the last position
of each axis when power is turned off.