Xantrex Technology XDC 80-75SL User Manual

Page 30

background image

Specifications and Characteristics

Output Performance Specifications

28

Operating Manual for XDC Series Slave Power Supply

Typical Programming Resolution

Typical Measurement Resolution

Programming Accuracy

1

Readback Accuracy

30 Minute Drift

2

Remote Digital Interface

Voltage
Current
Power
Over Voltage Protection

0.002% of Vmax
0.002% of Imax
0.05% of Pmax
0.002% of Vmax

Remote Digital Interface

Voltage
Current
Power

0.002% of Vmax
0.002% of Imax
0.05% of Pmax

Remote Digital Interface

Voltage Programming
Current Programming
Power Programming
Over voltage
Programming

0.1% of Vmax
0.5% of Imax
0.5% of Pmax
0.1% of Vmax

1. Accuracy specifications apply for settings in range of 1% to 100% of rated output

Remote Digital Interface

Voltage Readback
Current Readback
Power Readback

0.15% of Vmax
0.5% of Imax
0.5% of Pmax

Voltage

0.04% of Vmax

Current

0.6% of Imax

Power

1% of Pmax

2. At 25°C ±5°C, with full power load