Faults and Warnings
A fault affects the operation of the unit. A manual fault requires user
intervention by clearing the condition and then pressing the Reset button
on the inverter/charger’s front panel. See the System Control Panel
Owner’s Guide for information on clearing faults from the System
Control Panel.
A warning alerts you to a condition that could possibly affect operation of
the unit.
See “Faults and Warnings” on page 4–2 for more explanation on the
difference between faults and warnings.
Monitoring Status Messages on the System Control Panel
Refer to “System Menu Map” on page 3–3 of the Configuration chapter.
Bulk
Green
RS3000 is in bulk mode of battery
charging.
These lights indicate which
state of charge the RS3000 is in.
Absorption
Green
RS3000 is in absorption mode of
battery charging.
Float
Green
RS3000 is in float mode of battery
charging.
The Float light
illuminates in three-stage charging.
Equalize
Yellow
RS3000 is in equalize mode of
battery charging.
Table 2-2 Front Panel Lights
Light Illuminated
Color
Status
Action or Status Item