Monitoring the rs3000 indicator lights, Monitoring the rs – Xantrex Technology RS3000 User Manual
Page 43
![background image](/manuals/230330/43/background.png)
Operation
975-0170-01-01
2–13
Monitoring the RS3000 Indicator Lights
The ten indicator lights on the front panel show you the operating status
of the RS3000. A description of the lights is provided in Table 2-2.
If none of the front panel lights are on, see “Troubleshooting Reference”
on page 4–4.
t
Table 2-2 Front Panel Lights
Light Illuminated
Color
Status
Action or Status Item
External AC
Green
When the RS3000 is connected to a
qualified AC source or a generator,
the External AC light illuminates.
You can run your appliances
from an AC source like the
utility grid or a generator.
Inverter ON
Green
When the RS3000 is enabled (on)
and producing AC or load sensing,
the Inverter ON light illuminates.
This light is not illuminated if the
unit is charging.
You can run your appliances
from the inverter.
Low Battery
Yellow
When the Low Battery light
illuminates, the battery level is low.
You can run your appliances but
your battery level is low. Charge
your battery or connect to an
AC source or turn off the
inverter.
Network
Green
Indicates that there is activity on the
network.
Communication on the network
Fault
Red
A fault has occurred on the
network.
Investigate and clear the fault
condition.
Charger ON
Green
When the RS3000 is in charge
mode, the Charger ON light is
illuminated. In three-stage charging,
charging occurs in 3 stages: bulk,
absorption, and float. One of these 3
lights will be illuminated at the
same time the Charger ON light is
illuminated.
If the Charger ON light is off, the
RS3000 is not in any charge mode.
The charger is active and
charging your batteries. The
Charger ON light is always
illuminated if charging, whether
the unit is putting out current or
not.