Charger specifications – Xantrex Technology RS3000 User Manual
Page 101
Specifications
975-0170-01-01
A–3
Charger Specifications
All charging specifications are at nominal conditions: ambient
temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unless otherwise
specified.
Table A-2 Charger Specifications
Charging method
•
Three-stage charge (Bulk, Absorption, Float)
•
Two-stage charge (Bulk, Absorption)
The default charging method is three-stage.
Without a battery temperature
sensor
Three settings with the following temperature
values:
•
Cool 50 °F (10 °C)
•
Warm 77 °F (25 °C)
•
Hot 104 °F (40 °C)
The default value for this setting is Hot, and it can
only be changed by a dealer, factory, or service
centre.
With a battery temperature
sensor
The temperature compensation coefficients on a
12 volt battery are as follows:
•
Flooded: 27 mV × (25 °C – BTS °C)
•
Gel: 27 mV × (25 °C – BTS °C)
•
AGM: 21 mV × (25 °C – BTS °C)
Equalization cycle
Yes, manual via System Control Panel
Number of independent battery
banks
1
Battery bank size settings
50 – 2000 Ahr
Battery type settings
Flooded, AGM, Gel, Custom
Power factor corrected charging Yes
Input power factor at full
charge rate
> 0.95
AC input voltage
90 – 135 VAC
AC input frequency
60 Hz nominal, 55 – 65 Hz operating range
Minimum battery voltage
3.0 VDC
Maximum DC output voltage
16.0 VDC
Charger efficiency
≥ 85%
Maximum charge current
150 A