Table A-3 Transfer and General Specifications
Environmental Specifications
Table A-4 Environmental Specifications
Transfer time—utility to invert
20 ms
Minimum AC input voltage for transfer
90 VAC RMS
Maximum AC input voltage for transfer
135 VAC RMS
Minimum AC input frequency for transfer
55 Hz
Maximum AC input frequency for transfer 65 Hz
Cooling
Fan-cooled, temperature controlled.
Network power supply
800 mA at 15 VDC
Supported AC input types
Split phase (up to 50 amps per line)
Dual input (up to 25 amps per line)
Nominal Ambient temperature
77 °F (25 °C)
Full Power Operating Ambient
Temperature Range
–4 ° to 122 °F (–20 ° to 50 °C)
Maximum Operating Temperature
140 °F (60 °C) See “Invert Power
Derating vs Ambient Temperature” on
page A–6.
Storage temperature range
–40 ° to 185 °F (–40 to 85 °C)
Humidity: Operation/Storage