ColorWise Pro Tools for Windows and Mac OS computers are fundamentally the same.
The windows and dialog boxes illustrated are the Windows versions.

N

OTE

:

Changing the calibration has the potential to affect

all

jobs for

all

users, so you may

want to limit the number of people authorized to perform calibration.

T

O

CALIBRATE

THE

COPIER

USING

C

ALIBRATOR

1.

Launch ColorWise Pro Tools and connect to the Fiery.

For instructions on configuring the connection for ColorWise Pro Tools, see

Getting Started

.

2.

Click Calibrator.

The EFI ED-100 is available as a measurement method. This information is provided to
Calibrator by the Fiery. If the option does not appear, make sure you are connected to a
Fiery that supports the EFI ED-100. Not all Fierys support the EFI Densitometer ED-100.

N

OTE

:

It is very important that the copier you are calibrating and the computer that the

EFI ED-100 is connected to are connected to the same Fiery server. Also, be sure to print
the measurement patches from the copier you are calibrating, because the EFI ED-100 uses
formulas specific to the copier to convert the raw EFI ED-100 measurements into
ColorWise Calibrator compatible densities.