Fixing the stability chain, The battery, Pressure testing – Zanussi ZKG5020 User Manual
Page 29
IMPORTANT!
Flexible tubing used must comply with BS.
669 current edition.
LPG Flexible connections must be a type
suitable for L.P.G and capable of operation
up to 50 mbar and carry a red stripe, band
or label.
Fixing the stability chain
To further prevent tilting and for safe usage of
the appliance a stability chain should be used.
Unscrew the screw shown in the figure. Then,
align the first loop of the chain with the hole and
assemble with the screw so that the chain
stands in its place safely. Check the assembly
by gently pulling the chain from its loose end.
Fix the loose end to the rear wall as appropriate
for your kitchen. The chain is not supplied within
the package of the appliance, but can easily be
supplied from the market.
The battery
WARNING!
After unpacking, install the battery in the battery
box as explained below. The battery is placed
in the document bag.
1. The battery is located on the left hand side
of the front plinth.
2. To gain access to the battery, open the
main oven door and lift up the battery
holder lid.
3. Fit the new battery ensuring (+) terminal is
next to the (+) sign on the battery.
4. Close the lid of the battery holder.
Pressure testing
1. The Rapid injector is used as a pressure
test point.
2. Connect the pressure gauge to the Rapid
injector.
3. Check the supply pressure by turning the
Rapid burner on and one other hob burner
full on and light the appropriate burner.
The pressure should be either:
– For Natural Gas 20mbar
– For LP. Gas. The pressure must be set
to 29 mbar for use on butane or 37 mbar
for use on propane.
29