9. eXtended BuRnInG
9.1 It is possible to get the appliance to burn for extended
periods. In order to do this:
—
De-ash prior to final refuelling.
—
Set air controls to low combustion settings. This will
blacken the glass over night but it will clear when
operated at high output for a short period.
—
Use smokeless fuel or small, thick logs depending on fuel
desired.
10. oveR-FIRInG
10.1 Do not over-fill with fuel or use at maximum output for
long periods or over-firing can occur. If the flue pipe, flue
collar or top plate glow red the appliance is over-firing.
—
Close the air controls to reduce the output.
10.2 Over-firing can cause permanent damage to the appliance.
11. cHIMney FIRe
11.1 If a chimney fire occurs:
—
Shut all air controls immediately.
—
Evacuate the building.
—
Call the fire brigade.
—
Do not re-enter the building until it is confirmed safe.
11.2 do not use the appliance after a chimney fire until:
a) It has been inspected by a registered installer,
confirming the appliance is safe to use*.
b) The chimney system inspected and swept by a chimney
sweep, confirming the system is structurally sound and
free from obstruction before re-use**.
c) It is repaired as required before re-use. Use only
genuine Stovax replacement parts to keep your appliance
in safe and efficient working order.
useR InstRuctIons
11
PR8883
—
Place flat on the fixings on the bottom of the appliance
(see Diagram 12).
12
PR8884
—
Fit the plug supplied in the right hand side where the
riddling mechanism is located (see Diagram 13).
13
PR8454
Plug
Clamp
Bolt
—
Replace the log bar.