5.6 Burning Solid Fuel

Solid Fuel can only be burned in a multi-fuel stove.

Only for use with recommended fuels (see User

Instructions, Section 3).

Set air controls (see Diagram 9).

PR8727

Airwash: 50%

Primary Air: 50%

5.7 De-ash the fire bed before re-fuelling (see User Instructions,

Section 7).

—Open the Primary Air Control fully to establish a glowing

bed before adding new fuel.

—Burn new fuel at a high temperature for a few minutes

before adjusting the Primary Air Control to the desired

setting.

—Refuel little and often for clean, efficient burning.

5.8 Experience establishes control settings to suit personal

preferences.

5.9 Do not burn large amounts of fuel with the Primary Air

Control

on a low setting for long periods of time. This

reduces the glass cleaning effect of the Airwash and causes

tars and creosotes to build-up in the appliance and flue

system.

5.10 When in use, burning the appliance at a high temperature

for a short period also reduces tars and creosotes.

5.11 You must burn only anthracite or smokeless fuels

suitable for use in closed appliances

.

PR8742

Air Inlets

Log Guard

Mutli-fuel Stove

—Close the door.

5. RUNNING THE APPLIANCE

5.1 Burning Wood

—Close the Primary Air control and use the Airwash to

control the temperature (see Diagram 8).

PR8726

Airwash: Adjust

—Wood burns best on a bed of ash (approx. 25mm (1")

deep).

—Rake the embers evenly over the firebed and open

the Airwash Control fully for a few minutes before

re-fuelling.

5.2 Burn new logs at a high temperature for a few minutes

before adjusting the Airwash control.

Refuel little and often for clean, efficient burning.

5.3 Experience establishes settings to suit personal preferences.

5.4 Do not burn large amounts of fuel with the Airwash

Control

closed for long periods of time. This reduces the

glass cleaning effect and causes tars and creosotes to build-

up in the appliance and flue system.

5.5 When in use, burning the appliance at a high temperature

for a short period also reduces tars and creosotes.