USER INSTRUCTIONS

Do not burn construction timber, painted, impregnated

/ treated wood, manufactured board products or pallet

wood

.

3.2 Solid fuel

Burn only anthracite or manufactured briquette smokeless

fuels listed as suitable for use with closed heating

appliances.

Do not burn bituminous coal, ‘petro-coke’ or other

petroleum based fuels as this will invalidate the product

guarantee

.

3.3 Fuel consumption

As tested at nominal heat output to the requirements of EN

13240: 2001 for intermittent operation:

Description

Fuel Consumption

Kg/hour

Wood

Kg/hour

Briquette

Smokeless fuel

Yeoman CL 3

1.4

0.7

Yeoman CL 5

1.5

0.7

Yeoman CL 8

2.8

1.3

3.4 For advice on suitable solid fuels contact your local

approved coal merchant*.

A number of factors can affect the performance of the

appliance (see User Instructions, Section 6).

4. LIGHTING THE APPLIANCE

4.1 For best results:

—Set air controls (see Diagram 4).

PR8722

Airwash: Fully Open

Primary Air: Fully Open

—Place firelighters or paper and dry kindling wood on the

grate.

—Light the paper or firelighters (see Diagram 5).

—Leave the door slightly open as the fire establishes and

the glass warms to avoid the build-up of condensation.

—Add larger pieces of wood. Too many logs may smother

the fire.

Do not load fuel above the log guard and the secondary

combustion inlets at the back of the firebox (s

ee

Diagram 6).

PR8725

Air Inlets

Log Guard

Wood Stove

*In the U.K.

Ring the Solid Fuel Association advice line on

0845 601 4406 for details or visit their web site at

www.solidfuel.co.uk