PRE-INSTALLATION CHECKS

1. FLUE

Model

Yeoman CL3 - YM-CL3MF
Yeoman CL5 - YM-CL5W / YM-CL5MF
Yeoman CL8 - YM-CL8W / YM-CL8MF

Yeoman

CL3

Yeoman

CL5

Yeoman

CL8

Flue / Chimney Size

Without Liner System

Round (diameter)

mm

150

150

150

inch

6

6

6

Without Liner System (square)

Minimum Dimension

mm

135

135

135

inch

With Liner or Factory Made

System (diameter)

mm

‡150

150

150

mm

‡6

6

6

Flue / Chimney

minimum height*

m

4

4

4

feet

13

13

13

*When measured from the top of the flue, with no horizontal sections and a maximum of 4 bends with angles of less than 45°

‡May be 125mm (5") if burning low volatiles (smokeless) fuels approved for use in Smoke Control Areas.

See web site http://uksmokecontrolareas.co.uk for more information about approved fuels.

2. VENTILATION

2.1 This appliance requires a constant supply of air to maintain

proper combustion and effective flue performance.

2.2 An inadequate air supply can result in poor combustion and

smoke entering the room which is potentially dangerous.

2.3 This supply of air can come from either:

The natural leakage of air into the room in which the

product is fitted.

Purpose provided ventilation.

Some Stovax appliances can also be fitted with an

optional outdoor air kit which allows air to be drawn in

from the outside.

2.4 The amount of air required must comply with local building

regulations and the rules in force.

2.5 If spillage is detected during commissioning then there may

be insufficient natural ventilation and an additional air supply

will be necessary.

2.6 Many older buildings are sufficiently ventilated by natural

leakage of air to provide suitable air supply for an appliance

of 5kW output or less.

Modern building techniques have reduced the amount of air

that leaks in or out of a house. A modern construction with

an air tightness of less than 5m

3

per hour per m

2

requires an

air vent for ALL solid fuel appliances including those with a

rated heat output of less than 5kW.

NOTE: The air leakage of a modern house is tested at the

completion of construction and a certificate issued confirming

this.