5

USER INSTRUCTIONS

Airwash Control

CLOSE OPEN

Primary Control

CLOSE OPEN

PR8721

PR8722

DOOR OPERATION

1.14 Use a protected gloved hand to operate.

DO NOT OPEN THE DOOR WITH BARE HANDS

To Open and Close

Rotate handle and pull door to open

PR8723

PR8724

WARNING

Properly installed, operated and maintained this

appliance will not emit fumes into the room.

Occasional fumes from de-ashing and refuelling may occur.

Persistent fume emission is potentially dangerous and

must not be tolerated.

If fume emission does persist:

—Open doors and windows to ventilate the room.

—Allow fire to burn out and safely dispose of fuel from the

appliance.

—Check for chimney blockage and clean if required.

—Do not attempt to relight until the cause of the emission

has been identified and corrected.

If necessary seek expert advice.

—All open flued appliances can be affected by temporary

atmospheric conditions which may allow fumes to

enter the house. Because of this an electronic carbon

monoxide detector conforming to the latest edition

of BSEN50291 must be fitted in the same room as

the appliance. The existence of an alarm must not be

considered a substitute for ensuring regular servicing

and maintenance of the appliance and chimney system.

If the alarm sounds follow the instructions given under

Warning above.

2. USING THE APPLIANCE FOR THE FIRST

TIME

2.1 To allow the appliance to settle, and fixing glues and paint

to fully cure, operate the appliance at a low temperature for

the first few days.

2.2 Do not touch the paint during the first period of use.

2.3 During this time the appliance may give off some

unpleasant odours. Keep the room well ventilated to avoid

a build-up of fumes.

2.4 Please be aware that, during use, rope seals may discolour.

This is normal.

3. RECOMMENDED FUELS

3.1 Wood Logs

Burn only seasoned timber with a moisture content of less

than 20%. To ensure this allow cut wood to dry for 12 to

18 months.

Wood Length

Appliance

Wood Length

CL3

200mm

CL5

330mm

CL8

400mm

Poor quality timber:

—Causes low combustion efficiency.

—Produces harmful condensation.

—Reduces effectiveness of the airwash and life of the

appliance.