beautypg.com

User instructions, General points, Serial number – Yeoman YM-CL5MF User Manual

Page 4: Air controls

background image

4

USER INSTRUCTIONS

1. GENERAL POINTS

1.1 Before use of this appliance please read these

instructions fully.

The appliance must be fitted by a registered installer

*

, or

approved by your local building control officer.

1.2 All local regulations, including those referring to national

and European Standards need to be complied with when

installing the appliance.

1.3 Only use for domestic heating in accordance with these

operating instructions.

1.4 You must burn only approved fuels. Do not use with liquid

fuels or as an incinerator.

1.5 Appliance surfaces become very hot when in use. Use

a suitable fireguard if young children, elderly or infirm

persons are present.

Stovax offer firescreens, sparkguards and hearthgate systems

for protection‡. Your Yeoman retailer can advise you about

these products.

1.6 Do not place photographs, TV’s, paintings, porcelain or

other combustible items on the wall or near the appliance.

Exposure to hot temperatures will cause damage.

1.7 Extractor fans or cooker hoods must not be placed in the

same room or space as this can cause appliance to emit

fumes into the room.

1.8 Do not obstruct inside or outside ventilation required for

the safe use of this appliance.

1.9 Do not make unauthorised changes to the appliance.

1.10 The chimney must be swept at least once a year (see User

Instructions, Section 13).

1.11 Do not connect, or share, the same flue or chimney

system with another appliance.

1.12 This appliance is designed to be used with the doors shut.

SERIAL NUMBER

1.13 This number is required when ordering spare parts or

making warranty claims. It is found on the appliance data

plate.

Data Plate

PR8745

The data plate is found on a swing out data plate located

on the back of the stove on the left hand side (see

Diagram 1).

AIR CONTROLS

Triple Air Systems

This Yeoman appliance has a triple air system, providing

cleaner burning and greater efficiency and control (see

Diagram 2).

1) Airwash - air drawn over the window cleans the glass.

The source of Primary Combustion air when burning wood.

2) Primary Air - for use with solid fuel and when lighting

wood fires.

3) Cleanburn - secondary air is preheated through a heat

exchanger to combust unburned hydrocarbons, providing a

cleaner and more efficient burn.

PR8702

For Air Controls

see the diagram over.

Use the tool provided to operate the air controls.

Do not place tool on hot surfaces (e.g. top of stove)

.

‡In the U.K. these products must conform to the latest

edition of BS 8423, Fireguards for use with solid fuel

appliances.

If appliance is operating unattended they must conform to

the latest edition of BS 3248.

*Registered on the Competent Persons Scheme (GB only)

see page 26 / INFO (Republic of Ireland).

This manual is related to the following products: